Send Us Your Whatsapp Number For Updates.
Code:
Number:

Need
Help?
Live Chat
+92309-9142797
PRODUCTS DETAILS
NEW | USED
ATV610U55N4Z

Product Description:

Description

This Easy Altivar 610 drive is a frequency inverter for three-phase asynchronous motors. It works at a rated supply voltage from 380V to 460V AC. It is suitable for motors with power rating up to 5.5kW / 7.5hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 4kW / 5hp for applications requiring significant overload (up to 150%). It offers a plug & play solution, whereby parameters are preset in the factory to the desired configuration, to help save process control and operating time. It has integrated radio interference input filters in accordance with the EMC standard category C3 in environment 1 or 2. It weighs 3.940kg and its dimensions are, 130mm wide, 284mm high, 196mm deep. this drive has been specially designed for standard applications in the market segments water and wastewater and oil and gas and in the domains process and machine management and building management.

Specifications

Main

Range of product

Easy Altivar 610

Product or component type

Variable speed drive

Product specific application

Fan, pump, compressor, conveyor

Device short name

ATV610

variant

Standard version

Product destination

Asynchronous motors

Mounting mode

Cabinet mount

EMC filter

Integrated conforming to EN/IEC 61800-3 category C3 with 50 m

IP degree of protection

IP20

Type of cooling

Forced convection

Supply frequency

50...60 Hz +/-5 %

Network number of phases

3 phases

[Us] rated supply voltage

380...460 V - 15...10 %

Motor power kW

5.5 kW for normal duty
 4 kW for heavy duty

Motor power hp

7.5 hp for normal duty
 5 hp for heavy duty

Line current

11.6 A at 380 V (normal duty)
 10.5 A at 460 V (normal duty)
 8.9 A at 380 V (heavy duty)
 7.9 A at 460 V (heavy duty)

Prospective line Isc

22 kA

Apparent power

8.4 kVA at 460 V (normal duty)
 6.3 kVA at 460 V (heavy duty)

Continuous output current

10.5 A at 4 kHz for normal duty
 7.9 A at 4 kHz for heavy duty

Maximum transient current

14 A during 60 s (normal duty)
 14 A during 60 s (heavy duty)

Asynchronous motor control profile

Optimized torque mode
 Variable torque standard
 Constant torque standard

Output frequency

0.0001…0.5 kHz

Nominal switching frequency

4 kHz

Switching frequency

2...12 kHz adjustable

number of preset speeds

16 preset speeds

Communication port protocol

Modbus serial

Option card

Slot A: communication card, Profibus DP V1
 Slot A: digital or analog I/O extension card
 Slot A: relay output card

 

Complementary

Output voltage

<= power supply voltage

Motor slip compensation

Automatic whatever the load
 Adjustable
 Not available in permanent magnet motor law
 Can be suppressed

Acceleration and deceleration ramps

Linear adjustable separately from 0.01 to 9000 s
 S, U or customized

Braking to standstill

By DC injection

Protection type

Thermal protection: motor
 Motor phase break: motor
 Thermal protection: drive
 Overheating: drive
 Overcurrent between output phases and earth: drive
 Overload of output voltage: drive
 Short-circuit protection: drive
 Motor phase break: drive
 Overvoltages on the DC bus: drive
 Line supply overvoltage: drive
 Line supply undervoltage: drive
 Line supply phase loss: drive
 Overspeed: drive
 Break on the control circuit: drive

Frequency resolution

Display unit: 0.1 Hz
 Analog input: 0.012/50 Hz

Electrical connection

Control, screw terminal: 0.5...1.5 mm²
 Line side, screw terminal: 2.5...16 mm²
 Motor, screw terminal: 2.5...16 mm²

Connector type

1 RJ45 (on lower part) for Modbus serial

Physical interface

2-wire RS 485 for Modbus serial

Transmission frame

RTU for Modbus serial

Transmission rate

4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial

Type of polarization

No impedance for Modbus serial

Number of addresses

1…247 for Modbus serial

Method of access

Slave

Supply

External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
 Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection

Local signalling

2 LEDs for local diagnostic
 1 LED (yellow) for embedded communication status
 2 LEDs (dual colour) for communication module status
 1 LED (red) for presence of voltage

Width

130.0 mm

Height

284.0 mm

Depth

196.0 mm

Net weight

4.415 kg

Analogue input number

3

Analogue input type

AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits
 AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits
 AI2, AI3 software-configurable temperature probe or water level sensor

Discrete input number

6

Discrete input type

DI1...DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm
 DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)

Input compatibility

DI1...DI6: logic input level 1 PLC conforming to EN/IEC 61131-2
 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68

Discrete input logic

Positive logic (source): DI1...DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)
 Negative logic (sink): DI1...DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)
 Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)

Analogue output number

2

Analogue output type

Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits
 Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits

Sampling duration

5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input
 2 ms +/- 0.5 ms (DI1...DI6)configurable - discrete input
 5 ms +/- 1 ms (DI5, DI6)configurable - pulse input
 10 ms +/- 1 ms (AQ1, AQ2) - analog output

Accuracy

+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
 +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output

Linearity error

AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
 AQ1, AQ2: +/- 0.2 % for analog output

Relay output number

3

Relay output type

Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
 Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
 Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles

Refresh time

Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)

Minimum switching current

Relay output R1, R2, R3: 5 mA at 24 V DC

Maximum switching current

Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
 Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
 Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
 Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC

Isolation

Between power and control terminals

Insulation resistance

> 1 MOhm 500 V DC for 1 minute to earth

 

Environment

Noise level

55 dB conforming to 86/188/EEC

Power dissipation in W

171 W(forced convection) at 380 V, switching frequency 4 kHz
 35 W(natural convection) at 380 V, switching frequency 4 kHz

operating position

Vertical +/- 10 degree

Electromagnetic compatibility

Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6

Pollution degree

2 conforming to EN/IEC 61800-5-1

Vibration resistance

1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6

Shock resistance

15 gn for 11 ms conforming to IEC 60068-2-27

Relative humidity

5…95 % without condensation conforming to IEC 60068-2-3

Ambient air temperature for operation

-15…45 °C (without derating)
 45…60 °C (with derating factor)

Operating altitude

<= 1000 m without derating
 1000...4800 m with current derating 1 % per 100 m

Environmental characteristic

Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3

Standards

EN/IEC 61800-3
 Environment 2 category C3 EN/IEC 61800-3
 EN/IEC 61800-5-1
 IEC 60721-3

Marking

CE

 

Packing Units

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

19.7 cm

Package 1 Width

13.0 cm

Package 1 Length

28.6 cm

Package 1 Weight

3.94 kg

Unit Type of Package 2

S04

Number of Units in Package 2

3

Package 2 Height

30.0 cm

Package 2 Width

39.7 cm

Package 2 Length

59.8 cm

Package 2 Weight

13.07 kg

Powered by Froala Editor