Send Us Your Whatsapp Number For Updates.
Code:
Number:

Need
Help?
Live Chat
+92309-9142797
PRODUCTS DETAILS
NEW | USED
METSEPM5310

Product Description:

Description

This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 64 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to the 31st Harmonic. Include 256 kiloBytes of memory for two fixed parameters, active and reactive energy. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 415 VAC and 125 to 250 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 35 to 690 VAC at 47 to 63 Hz. Measurement range between Phase and Neutral is 20 to 400VAC at 47 to 63 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. The meter also has two digital inputs or digital outputs, configurable. There are 35 configurable alarms and it supports four tariff schedules. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 2.83 inches (72 millimetres), height 3.78 inches (96 millimetres) and product weight 15.2 onces (430 g).

Specifications

Main

Range

PowerLogic

Product name

PowerLogic PM5000

Device short name

PM5310

Product or component type

Power meter

 

Complementary

Power quality analysis

Up to the 31st harmonic

Device application

Multi-tariff
 Power monitoring

Type of measurement

Current
 Voltage
 Frequency
 Power factor
 Energy
 Active and reactive power

supply voltage

90...450 V AC 45...65 Hz
 100...300 V DC

Network frequency

50 Hz
 60 Hz

[In] rated current

1 A
 5 A

type of network

1P + N
 3P
 3P + N

Maximum power consumption in VA

11 VA at 415 V

Ride-through time

80 ms 120 V AC typical
 100 ms 230 V AC typical
 100 ms 415 V AC typical
 50 ms 125 V DC typical

Display type

Monochrome graphic LCD

Display resolution

128 x 128 pixels

Sampling rate

64 samples/cycle

Measurement current

5…8500 mA

Analogue input type

Voltage (impedance 5 MOhm)
 Current (impedance <= 0.3 mOhm)

Measurement voltage

35…760 V AC 45...65 Hz between phases
 20…440 V AC 45...65 Hz between phase and neutral

Frequency measurement range

45…65 Hz

Number of inputs

2 digital

Measurement accuracy

Active energy +/- 0.5 %
 Reactive energy +/- 2 %
 Active power +/- 0.5 %
 Apparent power +/- 0.5 %
 Frequency +/- 0.05 %
 Power factor +/- 0.5
 Current +/- 0.5 %
 Voltage +/- 0.5 %
 Apparent energy +/- 0.5 %
 Reactive power +/- 2 %

Accuracy class

Class 0.5S active energy conforming to IEC 62053-22

Number of outputs

2 digital

Information displayed

Tariff (4)

Communication port protocol

Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires, insulation 2500 V
 JBUS

Communication port support

RS485

Data recording

Event logs
 Min/max of instantaneous values
 Alarm logs
 Data logs
 Time stamping
 Maintenance logs

Memory capacity

256 kB

Connections - terminals

Voltage circuit: screw terminal block4
 Control circuit: screw terminal block2
 Current transformer: screw terminal block6
 Input/output circuit: screw terminal block6
 Relay output: screw terminal block4
 Ethernet network: RJ45 connector

Mounting mode

Flush-mounted

Mounting support

Framework

Standards

EN 50470-3
 IEC 62053-24
 IEC 60529
 EN 50470-1
 UL 61010-1
 IEC 62053-22
 IEC 61557-12

Product certifications

CE conforming to IEC 61010-1
 CULus conforming to UL 61010-1

Width

96 mm

Depth

72 mm

Height

96 mm

Net weight

430 g

 

Environment

Electromagnetic compatibility

Conducted and radiated emissions class A conforming to EN 55011
 Limits for harmonic current emissions class A conforming to IEC 61000-3-2
 Immunity to conducted disturbances - test level: 150 kHz...80 MHz level 3 conforming to IEC 61000-4-6
 Voltage dips and interruptions immunity test level 4 conforming to IEC 61000-4-11
 Conducted RF disturbances level 3 conforming to IEC 61000-4-6
 Magnetic field at power frequency level 4 conforming to IEC 61000-4-8
 Conducted and radiated emissions class B conforming to EN 55022
 Limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3
 Electrostatic discharge - test level: 8 kV level 4 conforming to IEC 61000-4-2
 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
 Surge immunity test level 4 conforming to IEC 61000-4-5
 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11

IP degree of protection

IP54 display: conforming to IEC 60529
 IP30 rear: conforming to IEC 60529

Relative humidity

5…95 % at 50 °C non-condensing

Pollution degree

2

Ambient air temperature for operation

-25…70 °C meter
 -20…70 °C display
 -25…-20 °C (with reduced performance) display

Ambient air temperature for storage

-40…85 °C

Operating altitude

2000 m CAT III
 3000 m CAT II

 

Packing Units

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

11.0 cm

Package 1 Width

12.6 cm

Package 1 Length

12.6 cm

Package 1 Weight

492.0 g

Unit Type of Package 2

S03

Number of Units in Package 2

12

Package 2 Height

30.0 cm

Package 2 Width

30.0 cm

Package 2 Length

40.0 cm

Package 2 Weight

6.4 kg

Unit Type of Package 3

P12

Number of Units in Package 3

288

Package 3 Height

105.0 cm

Package 3 Width

80.0 cm

Package 3 Length

120.0 cm

Package 3 Weight

156.0 kg

 

Powered by Froala Editor